Ensure that you have calibrated the camera first. |
Task 1: Obtain the Camera Model String
1. From the Server menu, select Manual Configuration Editor.
2. Expand Type: Camera
3. Find the ID of your camera and expand it.
4. Find the row where Section= Client and Key= DetectionXML.
5. In
the Value column, click the + sign to expand
the field. Copy the manufacturer and model name. For example:
<Manufacturer name='Axis'><Model name='AXIS
Q6035-E' type='PTZ Camera'>
Task 2: Copy calibrations settings from camera
1. Using the same camera ID from Obtain the Camera Model String, find the row where Section=PTZ Calibration and Key= PTZ Calibration
2. In the Value column, click the + sign to expand the field. Copy the contents of the Value field.
Task 3: Apply calibration settings copied from one camera to cameras of the same model
1. Expand Type: Global.
2. Click
Add a new setting... in the first row to activate
the cells.
Enter the following settings (indicated in bold font)
in the first row under the specific column headings:
Type = Global
ID
Section = PTZCalibrationOverride
Key = <Camera Model String>
Value = <XML Calibration String>
Where Key must be entered as <Manufacturer name><Space><Model
Name>. This information is from the Value
field for Key=DetectionXML that you found in Obtain
the Camera Model String. Using the example
from Task 1, <Manufacturer name><Space><Model
Name> would be Axis AXIS Q6305-E.
3. Paste contents you copied in Copy calibrations settings from camera (PTZ Calibration) into the Value field.
4. To confirm your entry, click the Action cell and click OK