Article Type:
|
How To
|
Product:
|
Symphony
|
Product Version:
|
7.1
|
Component:
|
Symphony Server
|
Device Brands:
|
|
Created:
|
5-Oct-2018 11:16:02 AM
|
Last Updated:
|
|
Integrate a Gallagher access control device
You can integrate a Gallagher access control device with Symphony to use events from the access control device to trigger alarms. To integrate a Gallagher access control device, complete the following workflow: - Configure the Gallagher access control device. For more information, visit the Gallagher support page.
- Create a read-only Gallagher database server.
- On the computer that hosts the Symphony Server, complete the following tasks to create the GallagherListener service:
- Install the OPC Core Components 3.00 Redistributable (x86) from the OPC Foundation.
- Install the Gallagher OPC Bridge Configuration Version 7.0.0.3 from Gallagher.
- Allow local access and remote access for the Anonymous Logon.
- Open a command prompt as an administrator.
- Type
sc create "AI GallagherListener" binPath = "c:\program files (86)\Senstar\Symphony\_bin\GallagherListener.exe" // - Restart the Symphony Server services.
- In the Symphony server configuration interface, add the Gallagher access control device. For more information, visit Add an access control device.
Average rating:
|
|
Please log in to rate.
|
Rated by 1, Viewed by 2107
|
|