Article Type:
|
Troubleshooting
|
Product:
|
Thin Client
|
Product Version:
|
|
Component:
|
Output
|
Device Brands:
|
|
Created:
|
2-Feb-2016 10:33:53 AM
|
Last Updated:
|
|
Thin Client 2.1.0 - Wrong time displayed in video decoration when connecting to cameras via Mobile Bridge
Issue:
When you connect to cameras via Mobile Bridge and you manually change the time in the Thin Client web interface, the time does NOT change on the video decoration. The time decoration in the video is always the time of the server to which the camera is connected.
Cause:
Thin Client converts the Symphony Server's Coordinated Universal Time (UTC) to local time and displays it in the video decoration. The time decoration therefore is not affected by local system time.
Reason:
This is necessary because of historical video, which must show the converted time from the server.
Important: If the time is changed when connecting directly to the camera, the updated time is displayed in the video decoration.