Knowledge Base Article
Article Type: Undocumented Settings
Product: E-Series Physical Security Applicance
Product Version:
Component:
Device Brands:
Created: 4-Sep-2012 11:36:41 AM
Last Updated:

Inputs/Outputs in E3200 and E7000

E3200

Serial numbers starting with: 32050, 32100

The I/O interface operates in wet contact mode:

Digital Inputs

  • To activate: Connect to 5V DC
  • To deactivate: Connect to ground

Digital Outputs

  • When activated: Outputs 5V DC
  • When deactivated: Connected to ground
  • Notes: Max. source current when active: 100 mA

E3200 POE, E7000

Serial numbers starting with: 32051, 32101, 7020, 7040 (Documented in manual)

The I/O interface operates in wet contact mode:

Digital Inputs

  • To activate: Connect to ground
  • To deactivate: Leave floating or unconnected
  • Notes: Source current when active: <1 mA

Digital Outputs

  • When activated: Connected to ground
  • When deactivated: Left floating
  • Notes: Max. sink current: 100 mA     Max. voltage: 5V DC

Average rating:
Please log in to rate.
Rated by 0, Viewed by 3881