Article Type:
|
How To
|
Product:
|
Symphony
|
Product Version:
|
|
Component:
|
Symphony Server
|
Device Brands:
|
|
Created:
|
19-Oct-2011 11:09:56 AM
|
Last Updated:
|
|
How to activate I/O on a Sony DH180 camera
Issue I/O does not work on Sony DH180. Possibly does not work on entire series.
Solution Activate I/O manually. Task 1 - Enable alarm output - Turn on the Sony camera.
- In a Web browser, connect to the Sony camera.
- Click Setup, and then Alarm Output.
- Click Alarm out 1 tab.
- Select the Alarm output On option.
Task 2 - Enable trigger to set alarm output - Click Setup and then Trigger.
- In the Trigger panel, click Alarm output 1 and select Toggle.
Senstar Software will send the following commands: - http://IP/command/main.cgi?Trigger=alarmout1on
- http://IP/command/main.cgi?Trigger=alarmout1off
Task 3 - Add the Sony camera to Senstar Symphony - Add Sony camera to Symphony.
- Use Alarm Console to activate/deactivate relay 1 on camera. The LED should turn on/off.