Article Type:
|
Error Message
|
Product:
|
Symphony
|
Product Version:
|
|
Component:
|
Symphony Client
|
Device Brands:
|
|
Created:
|
23-Sep-2011 2:56:52 PM
|
Last Updated:
|
|
screen must be at least "1024x768"
Issue - You are running Symphony on a low resolution monitor and you receive an error message that the screen must be at least "1024x768"
- Symphony Client does not launch
Solution You can remove the resolution check by editing the acc.ini file (%appdata%\Aimetis\acc.ini) - Edit the %appdata%\Aimetis\acc.ini file.
- Under the [main] section, add the following line.
CheckMinResolution=0
- Save the acc.ini file and restart Symphony Client for the changes to take effect.
Average rating:
|
|
Please log in to rate.
|
Rated by 0, Viewed by 4179
|
|